Hello folks,
I have been checking the numbers in BAD 582 following the recent
adjustments in the central value. I have included all the
calculations I did in
http://www.slac.stanford.edu/BFROOT/www/Physics/Analysis/AWG/InclusiveSL/islrecoil/VubB0Bch.xls
There are just minor adjustments in the systematic error.
I would like you to give a final look at it, in particular the OPE error
is 17.5% in BAD582 e 20% in BAD540. I assume 17.5% is the correct number,
but please correct me if I am wrong.
Once I get confirmation of this point I would like to post an HN in the
rev com pointing at the three postings that address the concerns of the
commettee asking for approval.
bye
ric
|