LISTSERV mailing list manager LISTSERV 16.5

Help for VUB-RECOIL Archives


VUB-RECOIL Archives

VUB-RECOIL Archives


VUB-RECOIL@LISTSERV.SLAC.STANFORD.EDU


View:

Message:

[

First

|

Previous

|

Next

|

Last

]

By Topic:

[

First

|

Previous

|

Next

|

Last

]

By Author:

[

First

|

Previous

|

Next

|

Last

]

Font:

Proportional Font

LISTSERV Archives

LISTSERV Archives

VUB-RECOIL Home

VUB-RECOIL Home

VUB-RECOIL  April 2004

VUB-RECOIL April 2004

Subject:

bremsstrahlung recovery for recoil analyses

From:

Daniele del Re <[log in to unmask]>

Date:

09 Apr 2004 16:39:52 -0700 (PDT)Fri, 09 Apr 2004 16:39:52 -0700 (PDT)

Content-Type:

TEXT/PLAIN

Parts/Attachments:

Parts/Attachments

TEXT/PLAIN (78 lines)


Hi all,

 when studying momentum resolution in lepton ID I realized that
that bremsstrahlung for electrons can introduce large biases in
p* efficiency and resolution. It can also affect the mm2 resolution
and finally it produces large biases in the inclusive Mx reconstruction.

 I the past we always neglected this point.

 A couple of examples. Here is the p* resolution comparison
between e and mu:

http://www.slac.stanford.edu/~daniele/exclvub/bremstudy/resoelemu.eps

 that shows that the effect is large. And this is mm2 for pi0lnu:

http://www.slac.stanford.edu/~daniele/exclvub/bremstudy/mm2pi0elemu.eps

(for the inclusive calculation of mm2 the effect is smaller because the
brem photon is included in the X system and then recoil has it).

 I implemented a brem recovery algorithm that is very similar to the one
in Beta. Code is in VubAnalysis (in util.icc).
 It is based on two variables

 - Delta(theta): it is the difference between the theta of the brem photon
   and the electron one. They should be the same within resolutions.

 - DD = (Phi(gamma)-Phi(e production))/Phi(e EMC)-Phi(e production)): here
   I am requesting that the phi of the gamma is in between the phi of the
   electron at the EMC and the phi at the origin. I used this ratio
   (instead of a simple cut on Phi(gamma)-Phi(e production) as in Beta)
   because numerator and denominator are somehow proportional.

 Here the distributions for electrons
 Delta(theta) (for -0.3<DD<0.6)
 http://www.slac.stanford.edu/~daniele/exclvub/bremstudy/Deltatheta.eps

 DD (for -0.04<Delta(theta)<0.04)
 http://www.slac.stanford.edu/~daniele/exclvub/bremstudy/DD.eps

 I finally select brem photon with these cuts
 -0.04<Delta(theta)<0.04 && -0.3<DD<0.6
 and I redefined the electron p4 as p4+p4(brem photon). Moreover the
brem photons are removed from the good photon list (goodPhoton[i] = 0)


 The following plots are a comparison with and without the correction:

 resolution in p*:
 http://www.slac.stanford.edu/~daniele/exclvub/bremstudy/resoelecorr.eps

 mm2 for pi0lnu:
 http://www.slac.stanford.edu/~daniele/exclvub/bremstudy/mm2pi0elecorr.eps

 inclusive mm2
 http://www.slac.stanford.edu/~daniele/exclvub/bremstudy/mm2elecorr.eps
 (small effect as expected, see above, mostly due to gain in p* cut
  efficiency)

 inclusive fitted X mass (mxhadfit)
 http://www.slac.stanford.edu/~daniele/exclvub/bremstudy/mxhadfitelecorr.eps


 Conclusions:
 - brem recovery improves largely the resolution in p* and the efficiency
   of p* cut (~+5%)
 - it improves mm2 resolution in exclusive calculation of mm2. total mm2
   cut efficiency increase by 10-15% depending on the mode.
 - the removal of brem photon changes and improves significantly the
   reconstruction of the inclusive X mass (mxhadfit)

 Daniele



Top of Message | Previous Page | Permalink

Advanced Options


Options

Log In

Log In

Get Password

Get Password


Search Archives

Search Archives


Subscribe or Unsubscribe

Subscribe or Unsubscribe


Archives

March 2010
December 2009
August 2009
January 2009
November 2008
October 2008
September 2008
August 2008
July 2008
June 2008
May 2008
April 2008
March 2008
February 2008
January 2008
November 2007
October 2007
September 2007
August 2007
July 2007
June 2007
May 2007
April 2007
March 2007
February 2007
January 2007
December 2006
November 2006
October 2006
September 2006
August 2006
July 2006
June 2006
May 2006
April 2006
March 2006
February 2006
January 2006
December 2005
November 2005
October 2005
September 2005
August 2005
July 2005
June 2005
May 2005
April 2005
March 2005
February 2005
January 2005
December 2004
November 2004
October 2004
September 2004
August 2004
July 2004
June 2004
May 2004
April 2004
March 2004
February 2004
January 2004
December 2003
November 2003
October 2003
September 2003
August 2003
July 2003
June 2003
May 2003
April 2003
March 2003
February 2003
January 2003
December 2002
November 2002
October 2002
September 2002
August 2002
July 2002
June 2002
May 2002
April 2002
March 2002
February 2002
January 2002
December 2001
November 2001
October 2001

ATOM RSS1 RSS2



LISTSERV.SLAC.STANFORD.EDU

Secured by F-Secure Anti-Virus CataList Email List Search Powered by the LISTSERV Email List Manager

Privacy Notice, Security Notice and Terms of Use