LISTSERV mailing list manager LISTSERV 16.5

Help for VUB-RECOIL Archives


VUB-RECOIL Archives

VUB-RECOIL Archives


VUB-RECOIL@LISTSERV.SLAC.STANFORD.EDU


View:

Message:

[

First

|

Previous

|

Next

|

Last

]

By Topic:

[

First

|

Previous

|

Next

|

Last

]

By Author:

[

First

|

Previous

|

Next

|

Last

]

Font:

Proportional Font

LISTSERV Archives

LISTSERV Archives

VUB-RECOIL Home

VUB-RECOIL Home

VUB-RECOIL  March 2006

VUB-RECOIL March 2006

Subject:

Truth matching in signal MC

From:

Kerstin Tackmann <[log in to unmask]>

Date:

9 Mar 2006 11:57:10 -0800 (PST)Thu, 9 Mar 2006 11:57:10 -0800 (PST)

Content-Type:

TEXT/PLAIN

Parts/Attachments:

Parts/Attachments

TEXT/PLAIN (57 lines)


Hi,

this is a little technical, but I would much appreaciate if some people
could look over this and give feedback.

I have recently seen - and Roberto said he had actually seen this since we
are working with the CM2 based ntuples - that in about 8% of all events in
signal MC we do not seem to have any truth match for the signal decay. My
knowledge about truth matching is quite limited so please correct me if
things I am writing do not make any sense or are wrong.

I understand that the current truth matching we do is based on the GHits.

RecoilMCUtil has a piece of code that actually takes the true Bs in the
event and looks for the one with a direct lepton daughter. This does not
get used for filling most of the truth variables, though, the GHit based
one is.
In the current implementation (running on nonres signal MC, one tcl file,
so the output ntuple has 3730 events), 597 events complain that they do
not have any B decaying semileptonically. Playing with this a little it
turns out that actually in these cases *both* B decay semileptonically
and that the current code picks up neither of them (because it wants
exactly one sl decay).

For the spectrum unfolding (and also for MC studies) it would be nice to
reduce this 8% inefficiency and have all (if possible) events have their
truth variables filled.

Here is my suggestion:
Why don't we do the truth matching as we did in CM1? I.e. we loop over the
true B and pick out the true semileptonic decay (rather than using the
GHit association). At least on signal MC, where we know we must have a
semileptonic decay. If we have two, we can still use the GHit association
to pick out the signal B or we could even be more aggressive and ask for
the Vub decay of the two (and use GHit association in case of two Vub
decays, that would also remove the Vcb decays in our signal MC).
I would put in an extra flag in RecoilMCUtil that would allow this and use
this option in VubXlnu.

Daniele, Roberto:
Am I missing some technicalities here? Does this sound ok and should/could
I put that in?

If the answers to the above questions are "yes":
Would we want to use this on generic MC as well (I would.)?

This seems to be a rather big chance and I might not be aware of all
consequences and I know we are not the only ones using this code, so I
better ask I guess...

Cheers,
Kerstin



Top of Message | Previous Page | Permalink

Advanced Options


Options

Log In

Log In

Get Password

Get Password


Search Archives

Search Archives


Subscribe or Unsubscribe

Subscribe or Unsubscribe


Archives

March 2010
December 2009
August 2009
January 2009
November 2008
October 2008
September 2008
August 2008
July 2008
June 2008
May 2008
April 2008
March 2008
February 2008
January 2008
November 2007
October 2007
September 2007
August 2007
July 2007
June 2007
May 2007
April 2007
March 2007
February 2007
January 2007
December 2006
November 2006
October 2006
September 2006
August 2006
July 2006
June 2006
May 2006
April 2006
March 2006
February 2006
January 2006
December 2005
November 2005
October 2005
September 2005
August 2005
July 2005
June 2005
May 2005
April 2005
March 2005
February 2005
January 2005
December 2004
November 2004
October 2004
September 2004
August 2004
July 2004
June 2004
May 2004
April 2004
March 2004
February 2004
January 2004
December 2003
November 2003
October 2003
September 2003
August 2003
July 2003
June 2003
May 2003
April 2003
March 2003
February 2003
January 2003
December 2002
November 2002
October 2002
September 2002
August 2002
July 2002
June 2002
May 2002
April 2002
March 2002
February 2002
January 2002
December 2001
November 2001
October 2001

ATOM RSS1 RSS2



LISTSERV.SLAC.STANFORD.EDU

Secured by F-Secure Anti-Virus CataList Email List Search Powered by the LISTSERV Email List Manager

Privacy Notice, Security Notice and Terms of Use