Hi Urs,

 few comments:

 1) the new plots look different than your previous ones but this could be
due just to the binning
 2) they are different from mine
(http://www.slac.stanford.edu/cgi-bin/lwgate/VUB-RECOIL/archives/vub-recoil.200301/Author/article-17.html).
The binning now is the same. May you tell me the exact cut you are
applying?

 Moreover I have the same questions as riccardo.

 Daniele

On Tue, 14 Jan 2003, Urs Langenegger wrote:

>
> Hoi,
>
> my go at the cross-wise comparison is in
>
>   http://www.slac.stanford.edu/~ursl/talks/011603/spectrum-a1060.eps.gz
>
> With respect to this morning I changed the binning (9 -> 10 bins), and
> the mX cut (now mX < 1.55 GeV, it used to be 1.6).
>
> The numbers don't show anything new we did not already see (imho).
>
> Cheers,
> --U.
>
>