Hello Folks,
today I have been playing around with the MC generator in order to try and
insert the new hybrid model in the ufficial production.
I am replacing the weights from Sven with the new bins:
in the decay.dec, it looks like
0.001365   Xu0   mu-  anti-nu_mu        PHOTOS VUB 4.8 1.29 0.22 20
  0.0 0.65 1.2 1.13 1.264 0.85 1.341 1.09 1.414 0.98 1.483 1.37 1.549
  1.46 1.612 1.50 1.673 1.54 1.732 1.55 1.788 1.51 1.843 1.57 1.897 1.53
  1.949 1.55 2.0 1.57 2.5 1.50 3.0 1.50 3.5 1.31  4.0 1.62 4.5 1.62;

I am right now putting the weights we obtained in order to reweight to the
current measurement (Br(b->ulnu)=2.1 10^-3). I am checking that I am
getting right normalization.

My question is :
	- do we want to change model everywhere ? Cocktail-Vub,
generic-Vub and generic-generic (the latter one will require checking with
the rest of ISL, but technical problems in pushing it though)?
	- is it ok to reweight to 2.1 10^-3 or do we want to reweight to
the rest of the world (1.7 10^-3)?

	bye
	ric