Hi Kerstin, sorry I missed the reading... for DQG-related reasons... Anyway, here are some replies to your questions: > * Why are we using the muMicroTight selector? The NN based muon selector > should give us higher efficiency and (substantially) lower fake rate. Hmmm, I guess it's my fault, for not changing the selector in our VubXlnuPhysics.tcl. I'm afraid it's a little too late to change that right now, at least in time for the review process. > * Are we using a cut on the impact parameter when performing the track > selection? This should reduce bkgds from material interaction in the > beam pipe. Should be answered by a look into the tcl files. Yes. It's defined by the following line in BRecoilUser/BRecoilCandidatesProcs.tcl: lappend config {GoodTracksVisibleESelection docaMax 1.5 } That's in centimeters. > * What exactly are we doing for PID weighting/killing/tweaking? > Should also be answered by a look into the tcl files. We are using tweaking; for the systematics we are doing what we did last year, that is the percentages of killing are defined in VubXlnu.tcl by the lines: # set ElectronKilling 0.02 # set MuonKilling 0.03 # set KKilling 0.02 # set ElectronMisIdKilling 0.15 # set MuonMisIdKilling 0.15 # set KMisIdKilling 0.15 > Also, I think we hadn't decided on when to have the next vu-recoil > meeting... Right. If we have a date for the AWG reading, it will be easier to decide. All the best, Roberto