Commit in hps-detectors/detectors/HPS-Test-JLAB-v3pt0 on MAIN
compact.xml+3-21.2 -> 1.3
some updates to the new detector with HPSEcal3 and vacuum chamber

hps-detectors/detectors/HPS-Test-JLAB-v3pt0
compact.xml 1.2 -> 1.3
diff -u -r1.2 -r1.3
--- compact.xml	31 Aug 2011 00:30:22 -0000	1.2
+++ compact.xml	2 Sep 2011 00:17:19 -0000	1.3
@@ -66,7 +66,7 @@
             <material name="LeadTungstate" />
             <dimensions x1="ecal_front" y1="ecal_front" x2="ecal_back" y2="ecal_back" z="ecal_z" />
             <layout beamgap="20.0*mm" nx="46" ny="5" dface="137.0*cm">
-                <remove ixmin="2" ixmax="7" iymin="-1" iymax="1" />
+                <remove ixmin="2" ixmax="10" iymin="-1" iymax="1" />
             </layout>
         </detector>
 
@@ -130,7 +130,8 @@
     <readouts>
         <readout name="EcalHits">
             <segmentation type="GridXYZ" gridSizeX="0.0" gridSizeY="0.0" gridSizeZ="0.0" />
-            <id>system:6,side:-2,layer:4,ix:-8,iy:4</id>
+            <!-- FIXME: Layer is a dummy number as this detector doesn't have layers. -->
+            <id>system:6,layer:2,ix:-8,iy:-6</id>
         </readout>      
         <readout name="TargetHits">
             <id>system:6,barrel:3,layer:4,wedge:4,module:12,sensor:1,side:32:-2,strip:12</id> 
CVSspam 0.2.8