Commit in hps-detectors/detectors/HPS-TestRun-v2 on MAIN | |||
HPS-TestRun-v2.lcdd | +4 | -3 | 1.8 -> 1.9 |
slight adjustment in flange Z pos
diff -u -r1.8 -r1.9 --- HPS-TestRun-v2.lcdd 5 Jun 2012 22:49:30 -0000 1.8 +++ HPS-TestRun-v2.lcdd 7 Jun 2012 17:55:17 -0000 1.9 @@ -1087,9 +1087,10 @@
<position name="crystal23-5_pos_neg_top" x="-298.998414441894" y="103.7427015552106" z="1601.0974000537913" unit="mm" /> <rotation name="crystal23-5_rot_neg_top" x="0.0759356980444989" y="0.3796784902224945" z="0.0" unit="radian" /> <constant name="flange_z" value="137.0" />
- <position name="FlangeWithHole_1inTopBoxpos" x="0.000000" y="0.000000" z="137.0" unit="cm" /> - <position name="Pipe_1inTopBoxpos" x="0.000000" y="0.000000" z="139.4765" unit="cm" /> - <position name="PipeFlange_1inTopBoxpos" x="0.000000" y="0.000000" z="141.953" unit="cm" />
+ <constant name="flange_z_corr" value="1.905/2" /> + <position name="FlangeWithHole_1inTopBoxpos" x="0.000000" y="0.000000" z="137.9525" unit="cm" /> + <position name="Pipe_1inTopBoxpos" x="0.000000" y="0.000000" z="140.429" unit="cm" /> + <position name="PipeFlange_1inTopBoxpos" x="0.000000" y="0.000000" z="142.9055" unit="cm" />
</define> <materials> <element Z="7" formula="N" name="N">
Use REPLY-ALL to reply to list
To unsubscribe from the LCD-CVS list, click the following link:
https://listserv.slac.stanford.edu/cgi-bin/wa?SUBED1=LCD-CVS&A=1