Commit in hps-detectors/gdml on MAIN | |||
vacuumChamber_v2.gdml | +2 | -3 | 1.1 -> 1.2 |
what the heck, I guess I can fix this FIXME, what a productive day
diff -u -r1.1 -r1.2 --- vacuumChamber_v2.gdml 8 May 2013 23:04:23 -0000 1.1 +++ vacuumChamber_v2.gdml 8 May 2013 23:13:59 -0000 1.2 @@ -2,13 +2,12 @@
<!-- Tessellated solid for electron run vacuum flange, flange face at z = 1351 mm, x offset 21.17 mm @author Sho Uemura <[log in to unmask]>
- @version $Id: vacuumChamber_v2.gdml,v 1.1 2013/05/08 23:04:23 meeg Exp $
+ @version $Id: vacuumChamber_v2.gdml,v 1.2 2013/05/08 23:13:59 meeg Exp $
--> <gdml xmlns:gdml="http://cern.ch/2001/Schemas/GDML" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://www.lcsim.org/schemas/gdml/1.0/gdml.xsd" > <define> <position name="p0" unit="mm" x="21.17" y="165" z="1538" />
- <!-- FIXME Use PI predefine. --> - <rotation name="r0" unit="radian" x="0" y="0" z="3.14159265" />
+ <rotation name="r0" unit="deg" x="0" y="0" z="180" />
<position name="v0" unit="mm" x="180" y="173" z="0" /> <position name="v1" unit="mm" x="180" y="157" z="-60" /> <position name="v2" unit="mm" x="240" y="173" z="0" />