Hello All, I've just checked in the new detector HPS-ECalCommissioning-v2. Salient features are: Changed the position of the top ECal crystals: BeamgapBottom = 20mm BeamgapTop = 23mm Evidently there are issues with the TOSCA simulations of the full 3D-3D field maps, so for the time being I have left the field as the box dipole. I changed the value of the central dipole field to: By = -0.3309 (The old value had been By=-1.5. Anyone know where this came from?) This value reflects a time average of the settings during the December running. If someone wants to calculate a luminosity-weighted average this can be changed. After this morning's discussion, I left the SVT in. Let me know if I got anything wrong or left anything out. Norman ######################################################################## Use REPLY-ALL to reply to list To unsubscribe from the HPS-SOFTWARE list, click the following link: https://listserv.slac.stanford.edu/cgi-bin/wa?SUBED1=HPS-SOFTWARE&A=1